BNE Series Electric Actuator for Rotary Valves - China Suppliers & Factory, 1500 N.m Explosion-Proof Automation Solutions
Explosion-proof realization
(1) Flame proof type (Exd)
(2) Explosion-proof rating
- Ex: Explosion-proof identification
- d: Explosion-proof type, expressed as "flameproof type"
- II: Device category, indicating electrical equipment for explosive gas environments other than coal mines
- C: Explosive level, which determines the dimensions (length and clearance) of each flame proof joint of the actuator
- T4: Temperature group, indicating that the maximum surface temperature of the actuator is allowed to be 135°C
- Gb: Indicates the protection level of the device
(3) Explosion-proof structure
BNE explosion-proof electric actuator instructions
- a. Packing and documents: ① product list, ② test report, ③ wiring diagram
- b. Inspection report: Nameplate and electrical wiring diagram must be consistent with the purchasing order
- c. Setting Limit switch: Before the end of setting Limit switch, do not make the actuator be in full-open or full-closed position
- d. Electrical wiring: After completing of electrical wiring, deal with cable interface in seal method
The name of the product structure and some parts
Product overview
Model designation
Construction features
Circuit diagram
BNE005 Overall dimensions and performance parameters
| Model | BNE005 | ||||
| Power supply | DC24V | AC24V | AC110V | AC220V | AC380V |
| Motor power | 20W | 15W | |||
| Rated current | 1.8A | 2A | 0.5A | 0.3A | 0.1A |
| Standard time/torque | 20S/50Nm | 30S/50Nm | |||
| Optional time/torque | 25S/80Nm | 30S/50Nm 15S/30Nm 30S/30Nm 30S/80Nm | |||
| Action type | S R P DC DR DP PL T | ||||
| Rotary Angle | 0-90° for option | ||||
| Withstand voltage | DC24V/AC24V 500VDC 60S AC110V/AC220V/AC380V 1500VAC 60S | ||||
| Insulation resistance | DC24V/AC24V 100MΩ/250VDC AC110V/AC220V/AC380V 100MΩ/500VAC | ||||
| Protection class | IP66 | ||||
| Electrical interface | Explosion-proof joint | ||||
| Protective device | (automatic recover type) thermal protector | ||||
| Limit switch | Electric work: close/open limit switch; Manual work: mechanical limit | ||||
| Installation Location | At any angle | ||||
| Working temperature | -20℃ - 60℃ | ||||
| Material of body | Aluminium alloy | ||||
| Optional function | Dehumidifying heater, clutch hand wheel | ||||
| Alternative model | BNE008 | ||||
BNE010 Overall dimensions and performance parameters
| Model | BNE010 | ||||
| Power supply | DC24V | AC24V | AC110V | AC220V | AC380V |
| Motor power | 25W | 25W | |||
| Rated current | 2A | 2.2A | 0.6A | 0.3A | 0.2A |
| Standard time/torque | 20S/100Nm | 30S/100Nm | |||
| Optional time/torque | 15S/100Nm 30S/150Nm | ||||
| Action type | S R P DC DR DP PL T | ||||
| Rotary Angle | 0-90° for option | ||||
| Withstand voltage | DC24V/AC24V 500VDC 60S AC110V/AC220V/AC380V 1500VAC 60S | ||||
| Insulation resistance | DC24V/AC24V 100MΩ/250VDC AC110V/AC220V/AC380V 100MΩ/500VAC | ||||
| Protection class | IP66 | ||||
| Electrical interface | Explosion-proof joint | ||||
| Protective device | (automatic recover type) thermal protector | ||||
| Limit switch | Electric work: close/open limit switch; Manual work: mechanical limit | ||||
| Installation location | At any angle | ||||
| Working temperature | -20℃ - 60℃ | ||||
| Material of body | Aluminium alloy | ||||
| Optional function | Dehumidifying heater, clutch hand wheel | ||||
| Alternative model | BNE015 | ||||
BNE020/040 Overall dimensions and performance parameters
| Model | BNE020 | BNE040 | |||||
| Power supply | DC24V | AC110V | AC220V | AC380V | AC110V | AC220V | AC380V |
| Motor power | 35W | 40W | 40W | 40W | 60W | 60W | 60W |
| Rated current | 4.5A | 0.8A | 0.4A | 0.2A | 1A | 0.5A | 0.3A |
| Standard time/torque | 20S/200Nm | 40S/200Nm | 40s/400Nm | ||||
| Optional time/torque | 20S/200Nm | 20S/400Nm | |||||
| Action type | S R P DC DR DP PL T | ||||||
| Rotary Angle | 0-90° for option | ||||||
| Withstand voltage | DC24V 500VDC 60S AC110V/AC220V/AC380V 1500VAC 60S | ||||||
| Insulation resistance | DC24V 100MΩ/250VDC AC110V/AC220V/AC380V 100MΩ/50VAC | ||||||
| Protection class | IP66 | ||||||
| Electrical Interface | Explosion-proof joint | ||||||
| Protective device | (automatic recover type) thermal protector | ||||||
| Limit switch | Electric work: close/open limit switch; Manual work: mechanical limit | ||||||
| Installation location | At any angle | ||||||
| Working temperature | -20℃ - 60℃ | ||||||
| Material of body | Aluminium alloy | ||||||
| Optional function | Dehumidifying heater, clutch hand wheel | ||||||
BNE060/100/150 Overall dimensions and performance parameters
| Model | BNE060 | BNE100 | BNE150 | |||||||
| Power supply | DC24V | AC110V | AC220V | AC380V | AC110V | AC220V | AC380V | AC110V | AC220V | AC380V |
| Motor power | 70W | 90W | 90W | 90W | 120W | 120W | 120W | 140W | 140W | 140W |
| Rated current | 7A | 2.2A | 1.1A | 0.3A | 2.4A | 1.2A | 0.4A | 2.6A | 1.3A | 0.4A |
| Standard time/torque | 20S/400Nm 30S/600Nm | 40S/600Nm | 40S/1000Nm | 55S/1500Nm | ||||||
| Action type | S R P DC DR DP PL T | |||||||||
| Rotary Angle | 0-90° for option | |||||||||
| Withstand voltage | DC24V 500VDC 60S AC110V/AC220V/AC380V 1500VAC 60S | |||||||||
| Insulation resistance | DC24b 100MΩ/250VDC AC110V/AC220V/AC380V 100MΩ/500VAC | |||||||||
| Protection class | IP65 | |||||||||
| Electrical interface | Explosion-proof joint | |||||||||
| Protective device | (automatic recover type) thermal protector | |||||||||
| Limit switch | Electric work: close/open limit switch; Manual work: mechanical limit | |||||||||
| Installation location | At any angle | |||||||||
| Working temperature | -20℃ - 60℃ | |||||||||
| Material of body | Aluminium alloy | |||||||||
| Optional function | Dehumidifying heater, clutch hand wheel | |||||||||
Installation and adjusting
1 Installation environment requirements
- 1) The types or categories of explosive media around the places of the devices must be in conformity to the explosion-proof regulation of this product.
- 2) Installed in a water flooded and outdoor place please explain in advance.
- 3) Please reserve wiring, maintenance space such as for manual operation.
- 4) In order to avoid the rain, direct sunlight, need to install the protection cover, or chooses IP67 protection level.
- 5) Basic installation direction to keep the window to the top, the vertical pipeline actuators installation, cable interface to the ground.
2 Ambient temperature, medium temperature
- 1) The ambient temperature is in the range of -30℃ - 60℃.
- 2) When the ambient temperature is below zero, install a dehumidifier in the machine.
- 3) When the working medium is high temperature, the bracket connected with the valve plays a role in reducing heat conduction.
- 4) When the working medium temperature is below 60℃, please choose standard support.
- 5) When the working medium temperature is above 60℃, please choose high temperature bracket.
3 Valve connection
- 1) Manually turn the valve, confirm that there is no abnormal situation, and turn to the fully closed position, and fix the support on the valve.
- 2) Place the electric actuator on the support and screw it on gently with bolts and nuts.
- 3) Turn the electric actuator to the closed position, and fix the valve core shaft and the electric actuator output shaft with the coupling and screw.
- 4) Use the handle to turn the electric actuator, the movement is smooth, be careful not to cross the set limit switch limit.
4 Adjustment
5 Test Operation
- • Confirm that the indication on the position meter and the valve opening are matching each other.
- • Confirm that the circuits are properly wired, also that the unit operates in correct direction with external switches.
- • Check the wiring diagram, power supply, input/output signal correctly.
- • Don't change the internal wiring.
- • Please check the rotating direction if the power supply is three-phase.
- • Make sure the actuator is in the on/off position, turn on the power and input the open signal.
- • If the actuator runs to the open direction, it means the wiring is correct.
- • If not, it must be changed 2 wiring lines of the 3 wiring lines.
6 Maintenance & lubrication
- 1) The product uses special molybdenum base grease, so there is no need to add oil.
- 2) Regular rotation: When the valve does not work for a long time, the machine can be driven regularly to check for abnormalities.
- 3) For control type (with field control) instructions, please refer to the actuator control module manual (technical document attachment).
Frequently Asked Questions (FAQ)
A: The explosion-proof grade is ExdIICT4Gb. This indicates a flameproof type (d) device category II (for explosive gas environments other than coal mines), explosive level C, temperature group T4 (maximum surface temperature allowed is 135°C), and equipment protection level Gb.
A: The Exd design allows an explosion to occur inside the equipment. The flameproof shell prevents internal sparks or explosion carriers from contacting the external environment. This is achieved through precise clearance, sufficient length of the flameproof surface, and a strong shell that withstands internal explosion pressure.
A: The surrounding explosive media must match the product's explosion-proof rating. For outdoor installations, a protective cover is recommended to prevent rain and direct sunlight unless an IP67 rating is chosen. Basic installation requires the window to face upwards and the cable interface to face the ground.
A: No, the product uses a special molybdenum base grease, so there is no need to add oil during maintenance.
A: Always cut the power off before manual operation. Insert the manual handle into the hexagonal hole under the rubber cap. Avoid excessive force when the actuator reaches full-open or full-closed positions to prevent damage to internal parts.
A: The actuator features a high-precision worm and gear mechanism. This design provides high transfer efficiency, outputs large torque, and prevents reverse transmission, ensuring the transmission remains stable and reliable.