Leave Your Message
BNE Series Electric Actuator

Electric Actuator

BNE Series Electric Actuator

BNE series explosion-proof electric actuator is used to control 0-270° rotary valve, such as butterfly valve, ball valve, throttle, baffle valves, plug valves, etc. Widely used in petroleum, chemical industry, water treatment, ship, paper, power stations, heating supply, building automation,light industry etc. 380V/220V/110V AC power supply for driving power supply 4-20 mA current signal, or 0-10 VDC voltage signal to be control signal, can make the valve movement to the required position, realize automation control. Maximum output torque is 1500 N.m

    ee6d101d-

    Explosion-proof realization

    GB3836 series standards specify different types of explosion-proof types and related design, manufacturing, inspection and testing standards.
    The explosion-proof type of BNE serie selectric actuator mechanism is "flame proof type" (Exd).
    (1)Flame proof type (Exd)
    The actuator allows an explosion to occur inside the equipment, and the flameproof surface of the shell is designed to prevent the internal sparkor the explosion carrier from contacting the outside world.The suitable flameproof surface clearance and sufficient length of the flameproof surface ensure product safety. At the sametime, the strong shell can with stand the high pressure generated by the internal explosion without being damaged. BNE explosion-proof series actuator in the motor cavity, electrical component cavityand Designed and manufactured according to the flameproof standard of the line cavity.
    (2)explosion-proof rating
    The explosion-proof grade of BNE explosion-proof electric actuatoris:ExdllCT4Gb
    Ex-Explosion-proofident ificationd-explosion-proof type,expressed as "flameprooftype";
    Il-Device category, indicating electrical equipment for explosive gas environments other than coal mines;
    C-Explosive level, which determines the dimensions (length and clearance) of each flame proof joint of the actuator;
    T4-temperature group, indicating that the maximum surface temperature of the actuatoris allowed to be 135°C;
    Gb-Indicates the protection level of the device.
    (3)explosion-proof structure hestructure of BNE series explosion-proof products conforms to the relevant provisions of GB3836.1-201《Explosive environment Part1:
    General requirements for equipment》and GB3836.2-2010《Explosive environment Part2:Equipment protected by flameproof housing"d"》
    standard,and adopts the flameproof structure of the whole machine.

    BNE explosion-proof electric actuator instructions
    Please read the instructions before using.Before installation and usage,plsconfirm as bellow:
    a.Packing and documents;
    ①product list②test report③wiring diagram;
    b.lnspection report;Nameplate;Electrical wiring diagramis consistent with purchasing order;
    c.Before the end of setting Limit switch.Do not make the actuator be infull-open orfull-closed;
    d.After Completing of electrical wiring,to deal with cable interface inseal method.

    The name of the product structure and some parts
    2
    Product overview
    BNE series explosion-proof electric actuatoris used tocontrol 0-270° rotary valve,such as butterfly valve, ball valve throttle, baffle valves,plug valves,etc.Widely used in petroleum,chemical industry, water treatment, ship, paper, power stations, heating supply, building automation, light industry etc.380v/220v/110v AC power supply for driving power supply, 4-20 mA current signal,or 0-10 VDC voltage signal to be control signal, can make the valve move mentto the required position,realize automation control.Maximum output torque is 1500 N.m

    Model designation
    3
    Construction features
    • Housing 
    Aluminum alloy housing,polyester powder coated, strong corrosion resistance, protection class is IP66.
    • Motor 
    Squirrel-cage motor,mall size,large torque low inertia insulation classis F, built-in overheat protction switch, can prevent the motor from overheating.
    • Manual operation
    Safe and reliable hand led esignis very easy for manual operation.But make sure the power is “oFF" before manual operation.When the handle is free,put it in the socket beside the body for keeping.
    • Dome indicator
    The sight mirror indicates clearly, and the observation is more intuitive and convenient.
    • Dryer
    Dryeris used to control the temperature and avoid actuator internal moisture conden sation caused by temperature or weather changes.
    To keep the electric elements dry.
    • Seal
    Good seals.Standard product protection gradeis IP66, and optional IP67.
    • Limit switch
    Mechanical and electronic double position limit.Mechanical limit screw is adjustable, safe and reliable; Electronic limit switch controlled by cam mechanism,easy adjusting the cam can set position accurately and conveniently, and is not affected by excessh and operation.
    • Self-locking
    The high precision worm and gear mechanism has high effectively transferand output large torque.And it‘s self-locking function, prevent
    reverse.transmission partisstable and reliable,no need more grease.
    • Anti-off bolt
    When remove the cover,the bol tattached to the shell,will not fall off.
    • Installation
    The bottom connectionis according to ISO5211/DiN3337.Can be installed in both vertical and horizontal installation.
    • Circuit
    Control circuit conforms to single or three-phase power supply standard,circuit layout is reasonable,compact terminals can effectively satisfy avariety of additional functional requirements.

    Circuit diagram123
    Note:The circuit diagram of the control type (with field control) is referred to the module manual.

    BNE005 Overall dimensions and performance parameters

    Model

    BNE005

    Power supply

    DC24V

    AC24V

    AC110V

    AC220V

    AC380V

    Motor power

    20W

    15W

    Rated current

    1.8A

    2A

    0.5A

    0.3A

    0.1A

    Standard time/torque

    20S/50Nm

    30S/50Nm

    Optional time/torque

    25S/80Nm

    30S/50Nm 15S/30Nm 30S/30Nm 30S/80Nm

    Action type

    S R P DC DR DP PL T

    Rotary Angle

    0-90°for option

    Withstandvoltage

    DC24V/AC24V 500VDC 60S AC110V/AC220V/AC380V 1500VAC 60S

    Insulation resistance

    DC24V/AC24V 100MΩ/250VDC AC110V/AC220V/AC380V 100MΩ/500VAC

    Protection class

    IP66

    Electrical interface

    Explosion-proof joint

    Protective device

    (automatic recover type)thermal protector

    Limit switch Electric work:close/open limit switch;Manul work:mechanical limit

    Installation Location

    At any angle

    Working temperature

    -20℃-60℃

    Material of body

    Aluminium alley

    Optional function

    Dehumidifying heater,clutch hand wheel

    Alternative model

    BNE008

    bne14

    BNE010 Overall dimensions and performance parameters
    Model BNE010
    Power supply DC24V AC24V AC110V AC220V AC380V
    Motor power 25W 25W
    Rated current 2A 2.2A 0.6A 0.3A 0.2A
    Standard  time/torque 20S/100Nm 30S/100Nm
    Optional  time/ torque 15S/100Nm 30S/150Nm
    Action type S R P  DC  DR  DP  PL T
    Rotary Angle 0-90°for option
    Withstandvoltage DC24V/AC24V 500VDC 60S AC110V/AC220V/AC380V 1500VAC 60S
    Insulation resistance DC24V/AC24V 100MΩ/250VDC AC110V/AC220V/AC380V 100MΩ/500VAC
    Protection class IP66
    Electrical interface Explosion-proof joint

    Protective device

    (automatic recover type)thermal protector
    Limit switch Electric work:close/open limit switch;Manual work:mechanical limit
    Installation location At any angle
    Working temperature -20℃-60℃
    Material of body Aluminium alloy
    Optional function Dehumidifying heater,clutch hand wheel

    Alternative model

    BNE015
    56

    BNE020/040 Overall dimensions and performance parameters
    Model BNE020 BNE040
    Power supply DC24V AC110V AC220V AC380V AC110V AC220V AC380V
    Motor power 35W 40W 40W 40W 60W 60W 60W
    Rated current 4.5A 0.8A 0.4A 0.2A 1A 0.5A 0.3A
    Standard  time/torque 20S/200Nm 40S/200Nm 40s/400Nm
    Optional  time/torque 20S/200Nm 20S/400Nm
    Action type S R P  DC  DR  DP  PL T
    Rotary Angle 0-90°for option
    Withstandvoltage DC24V 500VDC 60S AC110V/AC220V/AC380V 1500VAC 60S
    Insulation resistance DC24V 100MΩ/250VDC AC110V/AC220V/AC380V 100MΩ/50VAC
    Protection class IP66

    Electrical lnterface

    Explosion-proof joint

    Protective device

    (automatic recover type)thermal protector
    Limit switch Electric work:close/open limit switch;Manual work:mechanical limit
    Installation location At any angle
    Working temperature -20℃-60℃
    Material of body Aluminium alloy

    Optional function

    Dehumidifying heater,clutch hand wheel
    78

    BNE060/100/1500 verall dimensions and performance parameters
    Model BNE060 BNE100 BNE150
    Power supply DC24V AC110V AC220V AC380V AC110V AC220V AC380V AC110V AC220V AC380V
    Motor power 70W 90W 90W 90W 120W 120W 120W 140W 140W 140W
    Rated current 7A 2.2A 1.1A 0.3A 2.4A 1.2A 0.4A 2.6A 1.3A 0.4A
    Standard time/ torque 20S/400Nm 30S/600Nm 40S/600Nm 40S/1000Nm 55S/1500Nm
    Action type S R P DC  DR  DP  PL T
    Rotary Angle 0-90°for option
    Withstandvoltage DC24V 500VDC 60S AC110V/AC220V/  AC380V 1500VAC 60S
    Insulation resistance DC24b 100MΩ/250VDC AC110V/AC220V/AC380V 100MΩ/500VAC
    Protection class IP65

    Electrical interface

    Explosion-proof joint
    Protective device (automatic recover type)thermal protector
    Limit switch Electric worke:close/open limit switch;Manual work:mechanical limit
    Installation location At any angle
    Working temperature -20℃-60℃
    Material of body Aluminium alloy
    Optional function Dehumidifying heater,clutch hand wheel
    9

    Installation and adjusting

    1 Installation environment requirements
    1)The types or categories of explosve media around the places of the devices must bein conformity to the explosion-proof regulation of this product.
    2)Installed inawater flooded and outdoor please explaln inadvance.
    3)Please reserve wiring,main tenance space such as form anual operation.
    4)In order toavoidthe rain,direct sunlight,need to install the protection cover,or chooses IP67 protection level.
    5)Basic installation direction to keep the window to the top,thevertical pipeline actuators installation,cable interface to the ground.

    2 Ambient temperature,medium temperature
    1)The ambient temperature is in the range of-30℃-60℃ .
    2)When the amblent temperature is below zero,install adehumidifier in the machine.
    3)When the working mediumis hight emperature,the bracket connected with the valve plays arole in reducing heat   conduction. 
    4)When the working medium temperature is below 60*C, please choose standard support.
    5)When the working medium temperature is above 60℃, please choose high temperature bracket.

    3 Valve connection
    1)Manuallytum the valve,confirm that there is no abnormal situation, and turn to the fully closed position,and fixthe support
    on the valve.
    2)Place the electric actuatoron the suppor tand screwiton gently with bolts and nuts.
    3)Turn the electricactuator to the closed position,and fixth evalve core shaft and  the electric actuator output shaft with the coupling and screw.
    4)Use the handle to turm the electric actuator,the movement is smooth,be careful not to cross the set limit switch limit. Note:
    When installing,make sure that the switch of the actuator is consistent with the switch of the valve.The flange at the bottom of the actuator meets the IS0 5211 standard, and ifthevalve connected toital so meets this standard. It can be easily connected; If this standard is not met, anadditional bracket connection is required

    4 Adjustment
    1)Adjustment of Stroke limit
    Turn the handwheel to move the actuator to the position where the valve is fully closed.Then, loosen the limit CAM tightening nut with awrench,turn the limit CAM(yellow open,red close)to adjust it to just press the lower limit switch,and hear the'click sound for 2 times and then tighten the limit CAM,adjust the full close position, and set the full open position in the same way.     (As shownin Figure 12)
    10
    2)Adjustment of mechanical limit
    Loosen nut mechanical limit and then make suretheactuatormoveto the full-closed position.Rotate limiting nuts,then stop rotate when it comes across the fan-shaped gear inside and then screw out two circles and screw the nuts at last.(Shown in Figure13)
    3)Adjustment of potentiometer
    Potentiometer is output asa feedback signal in the actuator,with three output pins,the middle pinis the output,and the left and right sides are the power supply (note:the resistor should not have a resistance value of zero and jump phenomenon). Use the handle to turn the valve to the fully open position.Use a multimeter to measure the operation of the limilt switch. Adjust the pin resistance on the terminal to the range of 350-600.If it is not correct,it can be adjusted by turning the potentiometer trans mission gear,(As shown in Figure 14)

    5 TestOperation
    1)Manual Operation
    Cut power off be fore making manual operation.Insert the manual handle into the hexagonal hole under meaththe rubber cap.
    Note:Opening to Full open andfull-closed position,after the limit switch turn shalfdrcle,it will come across mechanical block.If rotate excessively,it would result the damage of other parts,solt should be awolded excessve force.
    2)Power operation
    Before making power operation:
    Confirm that the indication on the position meterand the valve opening are matching each other
    Confirm that the circuits are properly wired,also that the unit operates incorrect direction with external switches. 
    1)Check the wiringdiagram,power supply,input/output signal correctly.
    2)Don't change the internal wiring
    3)Please check therotatingdirection if the power supply is three-phase.
    4)Make sure the actuator bein the on/off position,turm on the power and input the open signa
    5)If the actuator runs to the open direction,it means the wiringis correct.
    6)If not,it must be changed 2 wiring  lines of the 3 wiring  line.

    6 Maintenance & lubrication
    1)The product uses special molybdenum base grease,so there is no need to add oil;
    2)Regular rotation:When the valve doesno work for alongtime,the machine can bedriven regularly to checkfo abnorm alities;
    3)For control type (with field control)structions,please refer to the actuator control module manual (technical document attachment)