Leave Your Message
BQ Series Electric Actuator BQ600 - 60Nm to 6000Nm, China Factory Suppliers, Explosion Proof, CE Certified
Hot Products

BQ Series Electric Actuator BQ600 - 60Nm to 6000Nm, China Factory Suppliers, Explosion Proof, CE Certified

Introducing the BQ600 model, a premium product from a leading China manufacturer specializing in industrial solutions. This versatile actuator offers an impressive output torque ranging from 60Nm to 6000N.m, making it ideal for a variety of applications. Crafted with durable aluminum alloy housing and finished with a robust epoxy coating, the BQ600 ensures longevity and reliability, Available in both ON/OFF and modulating types, this actuator is compliant with ISO5211 standards, meeting the demands of modern industrial settings. For added safety, we offer an explosion-proof option (EXDIIBTto enhance operational security. With CE certification, you can trust the quality and performance of our products, As a top-tier supplier in the industry, our factory is dedicated to producing high-performance actuators like the BQ600, ensuring that we meet the needs of our clients around the world. Choose quality and reliability with our innovative solutions today!

    Construction Model Instruction

    Construction Model Instruction

    Model Instructions

    Model Instructions

    Performance

    Performance
    Note
    Please contact us for other voltage request, e.g 110VAC/440VAC etc.

    Standard Specification

    Standard Specification

    Standard Configuration

    Join us to attend the MCE 2026 exhibition in Milan, Italy.
    Join us to attend the MCE 2026 exhibition in Milan, Italy.
    2026-03-19
    Electric explosion-proof clamp butterfly valve
    Electric explosion-proof clamp butterfly valve
    2026-03-09
    Electric plastic butterfly valves
    Electric plastic butterfly valves
    2026-03-04

    Dimension

    Dimension 1
    Dimension 2
    Dimension 3
    Dimension 4
    Note
    The mounting dimensions could be customized by the user.

    Setting

    1. Manual operation
    a. Pull the clutch handle towards the handwheel until it is upright.
    b. If the handle is not upright, pull it again and turn the handwheel slowly.
    c. Clockwise is the closed direction and counterclockwise is the open direction.
    d. Do not operate manually after the actuator is energized, and the handle will be restored to its original position automatically by the internal clutch mechanism.
    2. Limit switch setting
    a. Pull the handle for manual operation and rotate the handwheel to make the actuator run to the original position.
    b. Loosen the cam retaining bolt with a wrench, and rotate the cam to achieve the required adjustment angle (according to actual requirements of the valve) and tighten the bolt again.
    Limit switch setting
    3. Torque switch
    a. Torque switch has been set before delivery, the user does not need to set the switch again.
    Note: We cannot guarantee the performance if the switch is reset by the user.
    Torque switch setting
    4. Setting of stop bolt
    a. When the error is more than 5°, need to readjust the set retaining bolt.
    b. When setting, remove the stop bolt by 2 turns and tighten the nut.
    5. Indicator setting
    a. Make the actuator run to the closed position and rotate the actuator by hand.
    b. Align the number of the lens in the direction.
    c. Tighten the bolts (be careful not to touch the side of the indicator disc).
    Note: factory set, usually does not need to set again.
    6. Attention for connection
    a. The cable interface is G3/4″ screw hole, sealed with plug before delivery.
    b. If the user does not use either cable interface, please keep the plug as it is.
    c. Please seal the interface after wiring to prevent water inflow.
    d. If the user uses explosion-proof actuator, be sure to use same level connection components. If users use unqualified components, we cannot guarantee the performance of explosion-proof actuator.
    7. Electrical wiring
    a. A wiring diagram (inside the electrical hatch cover) is attached to the actuator.
    b. Wiring according to the wiring diagram provided, such as power supply, control power supply, internal wiring and grounding, etc. If necessary, the external electrical source is from the dryer to keep the actuator dry.
    d. Make sure the terminals are firmly connected.
    e. Make sure that an external controller operates only one actuator. (Can not operate more than 2 sets actuators at one time).
    f. Make sure the actuator is clean and free of sundries after wiring.
    8. Check the rotation direction
    a. For three-phase actuator, the rotation direction of the actuator should be checked before the electric operation (operator).
    b. If the direction of operation is incorrect, the limit switch will not work, resulting in plug damage or motor overheating.
    c. Manually put the actuator in the position of 50% on (or off), power the actuator, and confirm the direction of rotation.
    d. If the signal is on, the actuator will rotate and run in the open direction, then the direction is correct. But if you go to the other way, you need to change the wiring and switch any 2 of the 3 power cords.
    e. Check the rotation direction again and confirm it.
    Trial operation
    1. Make sure to check the rotation direction of the actuator before operation.
    2. Check the function of limit switch and torque switch, direction of indicator and space heater.
    3. Make sure the action of the handle is normal (clutch handle).
    4. Check the indicator light on the control panel.
    5. After the trial operation, please tighten the 4 bolts of the electrical hatch cover.
    Maintenance
    1. The actuator has been filled with the lubricants, it generally doesn’t need to add lubricants during normal operation.
    2. It’s better to keep the power supply for the actuator and have a run test every week regularly.
    3. For better performance of the actuator, it is highly suggested to do the regular inspection and maintenance once a year, together with checking the action status, surface corrosion, etc.

    Wiring Diagram

    BQ006/010 110V/220VAC 50/60HZ 1PH ON/OFF TYPE
    BQ006/010 110V/220VAC 50/60HZ 1PH ON/OFF TYPE
    BQ010 380V/440VAC 50/60HZ 3PH ON/OFF TYPE
    BQ010 380V/440VAC 50/60HZ 3PH ON/OFF TYPE
    BO020-BO600 110V/220VAC 50/60HZ 1PH ON/OFFTYPE
    BO020-BO600 110V/220VAC 50/60HZ 1PH ON/OFFTYPE
    BO020-BO600 380V/440VAC 50/60HZ 3PH ON/OFFTYPE
    BO020-BO600 380V/440VAC 50/60HZ 3PH ON/OFFTYPE
    BO006/010 110V/220VAC 50/60HZ 1PH MODULATINGTYPE
    BO006/010 110V/220VAC 50/60HZ 1PH MODULATINGTYPE
    BO010380V/440VAC 50/60HZ 3PH MODULATINGTYPE
    BO010380V/440VAC 50/60HZ 3PH MODULATINGTYPE
    BQ020-BQ600 110V/220VAC 50/60HZ 1PH MODULATING TYPE
    BQ020-BQ600 110V/220VAC 50/60HZ 1PH MODULATING TYPE
    BQ020-BQ600 380V/440VAC 50/60HZ 3PH MODULATING TYPE
    BQ020-BQ600 380V/440VAC 50/60HZ 3PH MODULATING TYPE
    Note
    1. The above wiring diagram is for reference only. Please refer to the standard wiring diagram inside of the actuator cover.
    2. For modulating type actuator, pls refer to the instructions of the actuator control module.
    Wiring diagram instructions note

    Frequently Asked Questions (FAQ)

    Q1: How do I switch the actuator to manual operation mode?
    To operate manually, pull the clutch handle towards the handwheel until it is upright. If it does not stay upright, pull it again and turn the handwheel slowly. Clockwise rotates to close and counterclockwise to open. The manual handle will automatically restore to its original position via the internal clutch mechanism once the actuator is energized.
    Q2: Can I adjust the torque switch settings?
    The torque switch is calibrated and set at the factory before delivery. Users do not need to adjust it. Please note that the manufacturer cannot guarantee the performance of the actuator if the torque switch is reset or tampered with by the user.
    Q3: What are the key precautions for electrical wiring?
    Wiring must strictly follow the wiring diagram provided inside the electrical hatch cover. Ensure all terminals are firmly connected. Keep in mind that an external controller must operate only one actuator; do not operate two or more actuators simultaneously with a single controller. Ensure the actuator remains clean and free of debris after wiring.
    Q4: How do I verify the rotation direction of a three-phase actuator?
    Manually position the actuator at 50% open/close, power it, and verify the rotation direction. If the direction is incorrect, the limit switch will fail to function, which can lead to plug damage or motor overheating. If it runs in the wrong direction, swap any two of the three power lines to correct the phase wiring.
    Q5: What maintenance is required for this electric actuator?
    The actuator is pre-filled with lubricants and generally does not require additional lubrication during normal operation. It is recommended to keep the power supply active and run a test test once a week. For optimal performance, a regular inspection and maintenance check (covering action status, surface corrosion, etc.) should be performed once a year.