BQ Series Electric Actuator - China Suppliers & Factory, Models BQ600 with Torque Range 60Nm to 6000Nm, Explosion Proof Options
Construction Model Instruction
Model Instructions
Performance
ℹ Note: Please contact us for other voltage request, e.g 110VAC/440VAC etc.
Standard Specification
Standard Configuration
01
Join us to attend the MCE 2026 exhibition in Milan, Italy.
2026-03-19
02
Electric explosion-proof clamp butterfly valve
2026-03-09
03
Electric plastic butterfly valves
2026-03-04
Dimension
ℹ Note: The mounting dimensions could be customized by the user.
Setting
1. Manual operation
a. Pull the clutch handle towards the handwheel until it is upright.
b. If the handle is not upright, pull it again and turn the handwheel slowly.
c. Clockwise is the closed direction and counterclockwise is the open direction.
d. Do not operate manually after the actuator is energized, and the handle will be restored to its original position automatically by the internal clutch mechanism.
2. Limit switch setting
a. Pull the handle for manual operation and rotate the handwheel to make the actuator run to the original position.
b. Loosen the cam retaining bolt with a wrench, and rotate the cam to achieve the required adjustment angle (according to actual requirements of the valve) and tighten the bolt again.
3. Torque switch
a. Torque switch has been set before delivery, the user does not need to set the switch again.
Note: We cannot guarantee the performance if the switch is reset by the user.
4. Setting of stop bolt
a. When the error is more than 5°, need to readjust set retaining bolt.
b. When setting, remove the stop bolt by 2 turns and tighten the nut.
5. Indicator setting
a. Make the actuator run to the closed position and rotate the actuator by hand.
b. Align the number of the lens in the direction.
c. Tighten the bolts (be careful not to touch the side of the indicator disc).
Note: factory set, usually does not need to set again.
6. Attention for connection
a. The cable interface is G3/4″ screw hole, sealed with plug before delivery.
b. If the user does not use either cable interface, please keep the plug as it is.
c. Please seal the interface after wiring to prevent water inflow.
d. If the user use explosion-proof actuator, be sure to use same level connection components. If users use unqualified components, we cannot guarantee the performance of explosion-proof actuator.
7. Electrical wiring
a. A wiring diagram (inside the electrical hatch cover) is attached to the actuator.
b. Wiring according to the wiring diagram provided, such as power supply, control power supply, internal wiring and grounding, etc. If necessary, the external electrical source is from the dryer to keep the actuator dry.
d. Make sure the terminals are firmly connected.
e. Make sure that an external controller operates only one actuator. (Can not operate more than 2 sets actuators at one time).
f. Make sure the actuator is clean and free of sundries after wiring.
8. Check the rotation direction
a. For three-phase actuator, the rotation direction of the actuator should be checked before the electric operation (operator).
b. If the direction of operation is incorrect, the limit switch will not work, resulting in plug damage or motor overheating.
c. Manually put the actuator in the position of 50% on (or off), power the actuator, and confirm the direction of rotation.
d. If the signal is on, the actuator will rotate and run in the open direction, then the direction is correct. But if you go to the other way, you need to change the wiring and switch any 2 of the 3 power cords.
e. Check the rotation direction again and confirm it.
Trial operation
1. Make sure to check the rotation direction of the actuator before operation.
2. Check the function of limit switch and torque switch, direction of indicator and space heater.
3. Make sure the action of the handle is normal (clutch handle).
4. Check the indicator light on the control panel.
5. After the trial operation, please tighten the 4 bolts of the electrical hatch cover.
Maintenance
1. The actuator has been filled with the lubricants, it generally doesn’t need to add lubricants during normal.
2. It’s better to keep the power supply for the actuator and have a run test every week regularly.
3. For better the performance of the actuator, it is highly suggested to do the regular inspection and maintenance once year, together with checking the action status, surface corrosion, etc.
Wiring Diagram
BQ006/010 110V/220VAC 50/60HZ 1PH ON/OFF TYPE
BQ010 380V/440VAC 50/60HZ 3PH ON/OFF TYPE
BO020-BO600 110V/220VAC 50/60HZ 1PH ON/OFFTYPE
BO020-BO600 380V/440VAC 50/60HZ 3PH ON/OFFTYPE
BO006/010 110V/220VAC 50/60HZ 1PH MODULATINGTYPE
BO010 380V/440VAC 50/60HZ 3PH MODULATINGTYPE
BQ020-BQ600 110V/220VAC 50/60HZ 1PH MODULATING TYPE
BQ020-BQ600 380V/440VAC 50/60HZ 3PH MODULATING TYPE
ℹ
Note:
1. The above wiring diagram is for reference only. Please refer to the standard wiring diagram inside of the actuator cover.
2. For modulating type actuator, pls refer to the instructions of the actuator control module.
Frequently Asked Questions (FAQ)
How do I switch the actuator to manual operation?
Pull the clutch handle towards the handwheel until it stands upright. If it does not stay upright, pull it again while turning the handwheel slowly. Note that you should not operate manually when the actuator is energized, as the handle will restore to its original position automatically.
Can I operate multiple actuators with a single external controller?
No, make sure that an external controller operates only one actuator at a time. Do not attempt to operate 2 or more actuators simultaneously with a single controller to avoid damage or malfunctions.
What should I check before powering a three-phase actuator?
You must verify the rotation direction of the actuator before electric operation. Manually set the actuator to the 50% open/closed position, apply power, and confirm the direction of rotation. If the direction is incorrect, swap any two of the three power cords to correct it.
Do I need to adjust the torque switch settings upon installation?
No, the torque switch is pre-set at the factory before delivery and does not need to be adjusted by the user. Readjusting or resetting the torque switch may compromise performance and void the product guarantee.
What is the recommended maintenance schedule for these actuators?
The actuator is pre-lubricated and does not require additional lubricants under normal use. It is recommended to perform a weekly run test and conduct a comprehensive inspection once a year, checking for surface corrosion and overall action status.