China BN Series Electric Actuator Suppliers - Economic Aluminum Alloy ON/OFF & Modulating Type Factory Solutions
BN Electric Actuator Instructions
Please read the instructions before using. Before installation and usage, please confirm as below:
a. Packing and documents: ① product list ② test report ③ wiring diagram;
b. Inspection report & Nameplate: Electrical wiring diagram must be consistent with the purchasing order;
c. Limit Switch Setting: Before the end of setting the limit switch, do not make the actuator be in full-open or full-closed status;
d. Cable Interface: After completing the electrical wiring, deal with the cable interface using a seal method.
The Name of the Product Structure and Some Parts
Product Overview
BN series electric actuator is used to control 0-270° rotary valves, such as butterfly valves, ball valves, throttles, baffle valves, plug valves, etc. It is widely used in petroleum, chemical industry, water treatment, ships, paper, power stations, heating supply, building automation, light industry, etc. 380V/220V/110V AC power supply for driving power supply, 4-20 mA current signal, or 0-10 VDC voltage signal to be control signal, can make the valve movement to the required position, realizing automation control. Maximum output torque is 1500N.m.
Model Designation
Construction Features
● Housing
Aluminum alloy housing, polyester powder coated, strong corrosion resistance, protection class is IP66.
● Motor
Squirrel-cage motor, small size, large torque, low inertia, insulation class is F, built-in overheat protection switch, can prevent the motor from overheating.
● Manual Operation
Safe and reliable handle design is very easy for manual operation. But make sure the power is "OFF" before manual operation. When the handle is free, put it in the socket beside the body for keeping.
● Dome Indicator
The sight mirror indicates clearly, and the observation is more intuitive and convenient.
● Dryer
Dryer is used to control the temperature and avoid actuator internal moisture condensation caused by temperature or weather changes to keep the electric elements dry.
● Seal
Good seals. Standard product protection grade is IP66, and optional IP67.
● Limit Switch
Mechanical and electronic double position limit. Mechanical limit screw is adjustable, safe and reliable; Electronic limit switch controlled by cam mechanism, easy adjusting the cam can set position accurately and conveniently, and is not affected by excess hand operation.
● Self-locking
The high precision worm and gear mechanism has high effectively transfer and output large torque. And its self-locking function prevents reverse. Transmission part is stable and reliable, no need for more grease.
● Anti-off Bolt
When removing the cover, the bolt attached to the shell will not fall off.
● Installation
The bottom connection is according to ISO 5211/DIN 3337. Can be installed in both vertical and horizontal installation.
● Circuit
Control circuit conforms to single or three-phase power supply standard, circuit layout is reasonable, compact terminals can effectively satisfy a variety of additional functional requirements.
Circuit Diagram
Note: The circuit diagram of the control type (with field control) is referred to the module manual.
BN003 Overall Dimensions and Performance Parameters
| Model | BN003 | |
| Power supply | DC24V | AC220V |
| Motor power | 15W | 18W |
| Rated current | 2A | 0.3A |
| Output torque | 10S/30Nm | 20S/30Nm |
| Action type | S R P DC DS DR DP | |
| Rotary Angle | 0-90° for option | |
| Withstand voltage | DC24V 500VDC 60S AC220V 1500VAC 60S | |
| Insulation resistance | 100MΩ/300VDC 100MΩ/500VDC | |
| Protection class | IP66 | |
| Conduit entry | 2×M16×1.5 waterproof cable gland | |
| Protective device | (automatic recover type) thermal protector | |
| Limit switch | Electric work: close/open limit switch Manual work: mechanical limit | |
| Installation location | At any angle | |
| Working temperature | -20℃-60℃ | |
| Material of body | Aluminium alloy | |
| Optional function | Clutch hand wheel | |
Fig 9
BN005 Overall Dimensions and Performance Parameters
| Model | BN005 | ||||
| Power supply | DC24V | AC24V | AC110V | AC220V | AC380V |
| Motor power | 20W | 15W | |||
| Rated current | 1.8A | 2A | 0.5A | 0.3A | 0.1A |
| Standard time/torque | 20S/50Nm | 30S/50Nm | |||
| Optional time/torque | 25S/80Nm | 30S/50Nm 15S/30Nm 30S/30Nm 30S/80Nm | |||
| Action type | S R P DC DS DR DP PL T | ||||
| Rotary Angle | 0-90° for option | ||||
| Withstand voltage | DC24V/AC24V 500VDC 60S AC110V/AC220V/AC380V 1500VAC 60S | ||||
| Insulation resistance | DC24V/AC24V 100MΩ/250VDC AC110V/AC220V/AC380V 100MΩ/500VAC | ||||
| Protection class | IP66 | ||||
| Conduit entry | 2×M18×1.5 waterproof cable gland | ||||
| Protective device | (automatic recover type) thermal protector | ||||
| Limit switch | Electric work: close/open limit switch Manual work: mechanical limit | ||||
| Installation location | At any angle | ||||
| Working temperature | -20℃-60℃ | ||||
| Material of body | Aluminium alloy | ||||
| Optional function | Dehumidifying heater, clutch hand wheel | ||||
| Alternative model | BN008 | ||||
Fig 10
BN010 Overall Dimensions and Performance Parameters
| Model | BN010 | ||||
| Power supply | DC24V | AC24V | AC110V | AC220V | AC380V |
| Motor power | 25W | 25W | |||
| Rated current | 2A | 2.2A | 0.6A | 0.3A | 0.2A |
| Standard time/torque | 20S/100Nm | 30S/100Nm | |||
| Optional time/torque | 15S/100Nm 30S/150Nm | ||||
| Action type | S R P DC DS DR DP PL T | ||||
| Rotary Angle | 0-90° for option | ||||
| Withstand voltage | DC24V/AC24V 500VDC 60S AC110V/AC220V/AC380V 1500VAC 60S | ||||
| Insulation resistance | DC24V/AC24V 100MΩ/250VDC AC110V/AC220V/AC380V 100MΩ/500VAC | ||||
| Protection class | IP66 | ||||
| Conduit entry | 2×M18×1.5 waterproof cable gland | ||||
| Protective device | (automatic recover type) thermal protector | ||||
| Limit switch | Electric work: close/open limit switch Manual work: mechanical limit | ||||
| Installation location | At any angle | ||||
| Working temperature | -20℃-60℃ | ||||
| Material of body | Aluminium alloy | ||||
| Optional function | Dehumidifying heater, clutch hand wheel | ||||
| Alternative model | BN015 | ||||
Fig 11
BN020/040 Overall Dimensions and Performance Parameters
| Model | BN020 | BN040 | |||||
| Power supply | DC24V | AC110V | AC220V | AC380V | AC110V | AC220V | AC380V |
| Motor power | 35W | 40W | 40W | 40W | 60W | 60W | 60W |
| Rated current | 4.5A | 0.8A | 0.4A | 0.2A | 1A | 0.5A | 0.3A |
| Standard time/torque | 20S/200Nm | 40S/200Nm | 40S/400Nm | ||||
| Optional time/torque | 20S/200Nm | 20S/400Nm | |||||
| Action type | S R P DC DS DR DP PL T | ||||||
| Rotary Angle | 0-90° for option | ||||||
| Withstand voltage | DC24V 500VDC 60S AC110V/AC220V/AC380V 1500VAC 60S | ||||||
| Insulation resistance | DC24V 100MΩ/250VDC AC110V/AC220V/AC380V 100MΩ/500VAC | ||||||
| Protection class | IP66 | ||||||
| Conduit entry | 2×M18×1.5 waterproof cable gland | ||||||
| Protective device | (automatic recover type) thermal protector | ||||||
| Limit switch | Electric work: close/open limit switch Manual work: mechanical limit | ||||||
| Installation location | At any angle | ||||||
| Working temperature | -20℃-60℃ | ||||||
| Material of body | Aluminium alloy | ||||||
| Optional function | Dehumidifying heater, clutch hand wheel | ||||||
Fig 12
BN060/100/150 Overall Dimensions and Performance Parameters
| Model | BN060 | BN100 | BN150 | |||||||
| Power supply | DC24V | AC110V | AC220V | AC380V | AC110V | AC220V | AC380V | AC110V | AC220V | AC380V |
| Motor power | 70W | 90W | 90W | 90W | 120W | 120W | 120W | 140W | 140W | 140W |
| Rated current | 7A | 2.2A | 1.1A | 0.3A | 2.4A | 1.2A | 0.4A | 2.6A | 1.3A | 0.4A |
| Standard time/torque | 20S/400Nm 30S/600Nm | 40S/600Nm | 40S/1000Nm | 55S/1500Nm | ||||||
| Action type | S R P DC DS DR DP PL T | |||||||||
| Rotary Angle | 0-90° for option | |||||||||
| Withstand voltage | DC24V 500VDC 60S AC110V/AC220V/AC380V 1500VAC 60S | |||||||||
| Insulation resistance | DC24V 100MΩ/250VDC AC110V/AC220V/AC380V 100MΩ/500VAC | |||||||||
| Protection class | IP66 | |||||||||
| Conduit entry | 2×M18×1.5 waterproof cable gland | |||||||||
| Protective device | (automatic recover type) thermal protector | |||||||||
| Limit switch | Electric work: close/open limit switch Manual work: mechanical limit | |||||||||
| Installation location | At any angle | |||||||||
| Working temperature | -20℃-60℃ | |||||||||
| Material of body | Aluminium alloy | |||||||||
| Optional function | Dehumidifying heater, clutch hand wheel | |||||||||
Fig 13
Installation and Adjusting
1. Installation Environment Requirements
1) This product is not explosion-proof. Do not use it in environments with flammable gas or corrosive gas.
2) If installed in a water-flooded or outdoor location, please explain in advance.
3) Please reserve wiring and maintenance space, such as for manual operation.
4) In order to avoid rain and direct sunlight, it is necessary to install a protection cover or choose an IP67 protection level.
5) Basic installation direction is to keep the window to the top. For vertical pipeline actuator installation, the cable interface should face the ground.
2) If installed in a water-flooded or outdoor location, please explain in advance.
3) Please reserve wiring and maintenance space, such as for manual operation.
4) In order to avoid rain and direct sunlight, it is necessary to install a protection cover or choose an IP67 protection level.
5) Basic installation direction is to keep the window to the top. For vertical pipeline actuator installation, the cable interface should face the ground.
2. Ambient Temperature, Medium Temperature
1) The ambient temperature is in the range of -30℃ ~ 60℃.
2) When the ambient temperature is below zero, install a dehumidifier in the machine.
3) When the working medium is high temperature, the bracket connected with the valve plays a role in reducing heat conduction.
4) When the working medium temperature is below 60℃, please choose the standard support.
5) When the working medium temperature is above 60℃, please choose the high-temperature bracket.
2) When the ambient temperature is below zero, install a dehumidifier in the machine.
3) When the working medium is high temperature, the bracket connected with the valve plays a role in reducing heat conduction.
4) When the working medium temperature is below 60℃, please choose the standard support.
5) When the working medium temperature is above 60℃, please choose the high-temperature bracket.
3. Valve Connection
1) Manually turn the valve, confirm that there is no abnormal situation, turn it to the fully closed position, and fix the support on the valve.
2) Place the electric actuator on the support and screw it on gently with bolts and nuts.
3) Turn the electric actuator to the closed position, and fix the valve core shaft and the electric actuator output shaft with the coupling and screw.
4) Use the handle to turn the electric actuator; the movement should be smooth. Be careful not to cross the set limit switch limit.
Note: When installing, make sure that the switch of the actuator is consistent with the switch of the valve. The flange at the bottom of the actuator meets the ISO5211 standard. If the valve connected to it also meets this standard, it can be easily connected; if this standard is not met, an additional bracket connection is required.
2) Place the electric actuator on the support and screw it on gently with bolts and nuts.
3) Turn the electric actuator to the closed position, and fix the valve core shaft and the electric actuator output shaft with the coupling and screw.
4) Use the handle to turn the electric actuator; the movement should be smooth. Be careful not to cross the set limit switch limit.
Note: When installing, make sure that the switch of the actuator is consistent with the switch of the valve. The flange at the bottom of the actuator meets the ISO5211 standard. If the valve connected to it also meets this standard, it can be easily connected; if this standard is not met, an additional bracket connection is required.
4. Adjustment
1) Adjustment of Stroke Limit:
Turn the handwheel to move the actuator to the position where the valve is fully closed. Then, loosen the limit CAM tightening nut with a wrench, turn the limit CAM (yellow for open, red for close) to adjust it to just press the lower limit switch, and hear the "click" sound 2 times. Then tighten the limit CAM, adjusting the full close position. Set the full open position in the same way (As shown in Figure 14).
Turn the handwheel to move the actuator to the position where the valve is fully closed. Then, loosen the limit CAM tightening nut with a wrench, turn the limit CAM (yellow for open, red for close) to adjust it to just press the lower limit switch, and hear the "click" sound 2 times. Then tighten the limit CAM, adjusting the full close position. Set the full open position in the same way (As shown in Figure 14).

Figure 14
2) Adjustment of Mechanical Limit:
Loosen the mechanical limit nut and make sure the actuator moves to the full-closed position. Rotate the limiting nuts, then stop rotating when it comes across the fan-shaped gear inside. Screw out two circles and finally screw the nuts (As shown in Figure 15).
Loosen the mechanical limit nut and make sure the actuator moves to the full-closed position. Rotate the limiting nuts, then stop rotating when it comes across the fan-shaped gear inside. Screw out two circles and finally screw the nuts (As shown in Figure 15).
3) Adjustment of Potentiometer:
The potentiometer outputs a feedback signal in the actuator with three output pins. The middle pin is the output, and the left and right sides are the power supply (Note: the resistor should not have a resistance value of zero and jump phenomenon). Use the handle to turn the valve to the fully open position. Use a multimeter to measure the operation of the limit switch. Adjust the pin resistance on the terminal to the range of 35Ω-60Ω. If it is not correct, it can be adjusted by turning the potentiometer transmission gear (As shown in Figure 16).
The potentiometer outputs a feedback signal in the actuator with three output pins. The middle pin is the output, and the left and right sides are the power supply (Note: the resistor should not have a resistance value of zero and jump phenomenon). Use the handle to turn the valve to the fully open position. Use a multimeter to measure the operation of the limit switch. Adjust the pin resistance on the terminal to the range of 35Ω-60Ω. If it is not correct, it can be adjusted by turning the potentiometer transmission gear (As shown in Figure 16).
5. Test Operation
1) Manual Operation:
Cut power off before making manual operations. Insert the manual handle into the hexagonal hole underneath the rubber cap.
Note: When opening to the full-open and full-closed positions, after the limit switch turns a half circle, it will encounter the mechanical block. If rotated excessively, it could result in damage to other parts, so excessive force should be avoided.
Cut power off before making manual operations. Insert the manual handle into the hexagonal hole underneath the rubber cap.
Note: When opening to the full-open and full-closed positions, after the limit switch turns a half circle, it will encounter the mechanical block. If rotated excessively, it could result in damage to other parts, so excessive force should be avoided.
2) Power Operation:
Before making power operations:
* Confirm that the indication on the position meter and the valve opening match each other.
* Confirm that the circuits are properly wired and that the unit operates in the correct direction with external switches.
1) Check the wiring diagram, power supply, and input/output signals correctly.
2) Don't change the internal wiring.
3) Please check the rotating direction if the power supply is three-phase.
4) Make sure the actuator is in the on/off position, turn on the power, and input the open signal.
5) If the actuator runs in the open direction, it means the wiring is correct.
6) If not, 2 wiring lines of the 3 wiring lines must be changed.
Before making power operations:
* Confirm that the indication on the position meter and the valve opening match each other.
* Confirm that the circuits are properly wired and that the unit operates in the correct direction with external switches.
1) Check the wiring diagram, power supply, and input/output signals correctly.
2) Don't change the internal wiring.
3) Please check the rotating direction if the power supply is three-phase.
4) Make sure the actuator is in the on/off position, turn on the power, and input the open signal.
5) If the actuator runs in the open direction, it means the wiring is correct.
6) If not, 2 wiring lines of the 3 wiring lines must be changed.
6. Maintenance & Lubrication
1) The product uses special molybdenum base grease, so there is no need to add oil.
2) Regular rotation: When the valve does not work for a long time, the machine can be driven regularly to check for abnormalities.
3) For control type (with field control) instructions, please refer to the actuator control module manual (technical document attachment).
2) Regular rotation: When the valve does not work for a long time, the machine can be driven regularly to check for abnormalities.
3) For control type (with field control) instructions, please refer to the actuator control module manual (technical document attachment).
Frequently Asked Questions (FAQ)
What should be checked before installing the BN electric actuator?
Before installation, verify the packing contents (product list, test report, wiring diagram), ensure the nameplate matches the purchase order, avoid putting the actuator in full-open or full-closed positions before limit switch settings are complete, and seal the cable interface after wiring.
What types of valves can the BN series electric actuator control?
The BN series electric actuator is designed to control 0-270° rotary valves, including butterfly valves, ball valves, throttles, baffle valves, and plug valves.
Can the actuator be operated manually, and what precautions are needed?
Yes, it has a handle for manual operation. Always ensure the power supply is turned "OFF" before operating manually, and avoid using excessive force to prevent damaging internal components when hitting mechanical blocks.
What is the protection grade of the housing and can it be used outdoors?
The standard protection grade is IP66, with an optional IP67. For outdoor installations, it is recommended to use a protective cover or choose the IP67 protection level to shield it from rain and direct sunlight.
Does the actuator require regular lubrication or oil changes?
No. The actuator is pre-lubricated with a special molybdenum base grease, meaning there is no need to add oil during its operational lifespan.
How do I adjust the stroke limit of the valve?
Turn the handwheel to close the valve fully, loosen the limit CAM tightening nut, rotate the limit CAM (yellow for open, red for close) until it presses the lower limit switch and clicks twice, then tighten the nut. Repeat the same process for the fully open position.