Leave Your Message
Selection of pneumatic actuator cylinder solenoid valve
News

Selection of pneumatic actuator cylinder solenoid valve

2025-05-09

Users generally have a better understanding of  pneumatic actuators, and they do not know much about the accessories of Pneumatic Actuators, but in fact, the role and importance of accessories as Pneumatic Actuators are not lower than that of pneumatic actuators themselves. Let's take a detailed analysis of one of the accessories of pneumatic actuators - solenoid valves. 

1. the introduction of Pneumatic Actuator solenoid valve
Solenoid valves are used for electronically controlled operation of pneumatic valves "on" or "off". Compliant with NAMUR connection standards, it is mounted directly on the side of the pneumatic actuator without the need for a pipe connection. According to the needs of the instrument control system, single electronic control or double electric control can be selected. The two-position five-way solenoid valve is equipped with a double-acting actuator, and the two-position three-way solenoid valve is equipped with a single-acting actuator. At the same time, the product has basic type (IP67) and explosion-proof type, and the explosion-proof level is Ex dIIBT4, which is explosion-proof and suitable for explosive environment places in the factory. It is also possible to select the appropriate voltage according to the needs.

2. Technical parameters of pneumatic actuator solenoid valve.
Structural form: sliding
Mode of action: electromagnet or manual operation.

Manual status locking can be achieved by pressing and rotating the manual action knob.
Return mode: pneumatic spring return, mechanical spring return, electromagnet operation return.
Interface: ISO228/1 standard G1/4
Ambient temperature: -20°C~+60 (explosion-proof type -15°C~+50°C)
Medium temperature: -20°C~+80°C (explosion-proof type -15°C~+50°C)
Material: valve body and internal parts: anodic electroplated aluminum alloy, copper.
Reinforced end caps: Plastic.
Seals: styrene-butadiene rubber (NBR) and polyurethane (AU).
Installation: Double bore according to NAMUR standard and VDI/VDE3845

3. Pneumatic actuator solenoid valve air circuit device
Function: 2-bit 3CH NC (V45C2), 2-bit 5CH (V45K2)
Media: filtered (50 μm), lubricated or non-lubricated compressed air, and dry dew point to -20°C,
Rated flow: V45K2 type: QNn=1060N1/min,
     V45C2 type: 1-2QNn-1060N1/min, 2-3QNn=1060N1/min
DN: DN7mm
Commutation time: about 40 ms
Special equipment: explosion-proof coil EExmT6
How is the solenoid valve connected to the pneumatic actuator?
There are two connection methods, one is the pipe connection and the other is the Namur connection, the pipe connection is connected to the cylinder with a stainless steel pipe, and the Namur connection is to paste the solenoid valve directly to the imported pneumatic actuator, but this requires the cylinder to meet the Namur standard. Generally speaking, quarter-turn imported  pneumatic actuators  can be connected with Namur or tubular connections, while linear cylinders can only be connected with tubular connections.